Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37738643

RESUMO

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation (AF). There are limited data on the PolarX Cryoballoon. The study aimed to establish the safety, efficacy, and feasibility of same day discharge for Cryoballoon PVI. METHODS AND RESULTS: Multi-centre study across 12 centres. Procedural metrics, safety profile, and procedural efficacy of the PolarX Cryoballoon with the Arctic Front Advance (AFA) Cryoballoon were compared in a cohort large enough to provide definitive comparative data. A total of 1688 patients underwent PVI with cryoablation (50% PolarX and 50% AFA). Successful PVI was achieved with 1677 (99.3%) patients with 97.2% (n = 1641) performed as day case procedures with a complication rate of <1%. Safety, procedural metrics, and efficacy of the PolarX Cryoballoon were comparable with the AFA cohort. The PolarX Cryoballoon demonstrated a nadir temperature of -54.6 ± 7.6°C, temperature at 30 s of -38.6 ± 7.2°C, time to -40°C of 34.1 ± 13.7 s, and time to isolation of 49.8 ± 33.2 s. Independent predictors for achieving PVI included time to reach -40°C [odds ratio (OR) 1.34; P < 0.001] and nadir temperature (OR 1.24; P < 0.001) with an optimal cut-off of ≤34 s [area under the curve (AUC) 0.73; P < 0.001] and nadir temperature of ≤-54.0°C (AUC 0.71; P < 0.001), respectively. CONCLUSIONS: This large-scale UK multi-centre study has shown that Cryoballoon PVI is a safe, effective day case procedure. PVI using the PolarX Cryoballoon was similarly safe and effective as the AFA Cryoballoon. The cryoablation metrics achieved with the PolarX Cryoballoon were different to that reported with the AFA Cryoballoon. Modified cryoablation targets are required when utilizing the PolarX Cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Fatores de Tempo , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Reino Unido , Recidiva
2.
Circ Arrhythm Electrophysiol ; 16(9): e011870, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37646176

RESUMO

BACKGROUND: Hypoxia-ischemia predisposes to atrial arrhythmia. Atrial ATP-sensitive potassium channel (KATP) modulation during hypoxia has not been explored. We investigated the effects of hypoxia on atrial electrophysiology in mice with global deletion of KATP pore-forming subunits. METHODS: Whole heart KATP RNA expression was probed. Whole-cell KATP current and action potentials were recorded in isolated wild-type (WT), Kir6.1 global knockout (6.1-gKO), and Kir6.2 global knockout (6.2-gKO) murine atrial myocytes. Langendorff-perfused hearts were assessed for atrial effective refractory period (ERP), conduction velocity, wavefront path length (WFPL), and arrhymogenicity under normoxia/hypoxia using a microelectrode array and programmed electrical stimulation. Heart histology was assessed. RESULTS: Expression patterns were essentially identical for all KATP subunit RNA across human heart, whereas in mouse, Kir6.1 and SUR2 (sulphonylurea receptor subunit) were higher in ventricle than atrium, and Kir6.2 and SUR1 were higher in atrium. Compared with WT, 6.2-gKO atrial myocytes had reduced tolbutamide-sensitive current and action potentials were more depolarized with slower upstroke and reduced peak amplitude. Action potential duration was prolonged in 6.1-gKO atrial myocytes, absent of changes in other ion channel gene expression or atrial myocyte hypertrophy. In Langendorff-perfused hearts, baseline atrial ERP was prolonged and conduction velocity reduced in both KATP knockout mice compared with WT, without histological fibrosis. Compared with baseline, hypoxia led to conduction velocity slowing, stable ERP, and WFPL shortening in WT and 6.1-gKO hearts, whereas WFPL was stable in 6.2-gKO hearts due to ERP prolongation with conduction velocity slowing. Tolbutamide reversed hypoxia-induced WFPL shortening in WT and 6.1-gKO hearts through ERP prolongation. Atrial tachyarrhythmias inducible with programmed electrical stimulation during hypoxia in WT and 6.1-gKO mice correlated with WFPL shortening. Spontaneous arrhythmia was not seen. CONCLUSIONS: KATP block/absence leads to cellular and tissue level atrial electrophysiological modification. Kir6.2 global knockout prevents hypoxia-induced atrial WFPL shortening and atrial arrhythmogenicity to programmed electrical stimulation. This mechanism could be explored translationally to treat ischemically driven atrial arrhythmia.


Assuntos
Fibrilação Atrial , Canais KATP , Humanos , Animais , Camundongos , Canais KATP/genética , Fibrilação Atrial/genética , Tolbutamida , Taquicardia , Átrios do Coração , Hipóxia/complicações , Hipóxia/genética , Trifosfato de Adenosina
3.
Europace ; 24(9): 1420-1429, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35737685

RESUMO

AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30 s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30 s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5 s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30 s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0 s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 8(2): 225-235, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35210080

RESUMO

OBJECTIVES: The purpose of this study was to assess the performance and limitations of low-voltage zones (LVZ) localization by optimized late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) scar imaging in patients with cardiac implantable electronic devices (CIEDs). BACKGROUND: Scar evaluation by LGE-CMR can assist ventricular tachycardia (VT) ablation, but challenges with electroanatomical maps coregistration and presence of imaging artefacts from CIED limit accuracy. METHODS: A total of 10 patients underwent VT ablation and preprocedural LGE-CMR using wideband imaging. Scar was segmented from CMR pixel signal intensity maps using commercial software (ADAS-VT, Galgo Medical) with bespoke tools and compared with detailed electroanatomical maps (CARTO). Coregistration of EP and imaging-derived scar was performed using the aorta as a fiducial marker, and the impact of coregistration was determined by assessing intraobserver/interobserver variability and using computer simulations. Spatial smoothing was applied to assess correlation at different spatial resolutions and to reduce noise. RESULTS: Pixel signal intensity maps localized low-voltage zones (V <1.5 mV) with area under the receiver-operating characteristic curve: 0.82 (interquartile range [IQR]: 0.76-0.83), sensitivity 74% (IQR: 71%-77%), and specificity 78% (IQR: 73%-83%) and correlated with bipolar voltage (r = -0.57 [IQR: -0.68 to -0.42]) across patients. In simulations, small random shifts and rotations worsened LVZ localization in at least some cases. The use of the full aortic geometry ensured high reproducibility of LVZ localization (r >0.86 for area under the receiver-operating characteristic curve). Spatial smoothing improved localization of LVZ. Results for LVZ with V <0.5 mV were similar. CONCLUSIONS: In patients with CIEDs, novel wideband CMR sequences and personalized coregistration strategies can localize LVZ with good accuracy and may assist VT ablation procedures.


Assuntos
Meios de Contraste , Taquicardia Ventricular , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia
5.
JCI Insight ; 6(16)2021 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-34283808

RESUMO

BACKGROUNDEpicardial adipose tissue (EAT) directly overlies the myocardium, with changes in its morphology and volume associated with myriad cardiovascular and metabolic diseases. However, EAT's immune structure and cellular characterization remain incompletely described. We aimed to define the immune phenotype of EAT in humans and compare such profiles across lean, obese, and diabetic patients.METHODSWe recruited 152 patients undergoing open-chest coronary artery bypass grafting (CABG), valve repair/replacement (VR) surgery, or combined CABG/VR. Patients' clinical and biochemical data and EAT, subcutaneous adipose tissue (SAT), and preoperative blood samples were collected. Immune cell profiling was evaluated by flow cytometry and complemented by gene expression studies of immune mediators. Bulk RNA-Seq was performed in EAT across metabolic profiles to assess whole-transcriptome changes observed in lean, obese, and diabetic groups.RESULTSFlow cytometry analysis demonstrated EAT was highly enriched in adaptive immune (T and B) cells. Although overweight/obese and diabetic patients had similar EAT cellular profiles to lean control patients, the EAT exhibited significantly (P ≤ 0.01) raised expression of immune mediators, including IL-1, IL-6, TNF-α, and IFN-γ. These changes were not observed in SAT or blood. Neither underlying coronary artery disease nor the presence of hypertension significantly altered the immune profiles observed. Bulk RNA-Seq demonstrated significant alterations in metabolic and inflammatory pathways in the EAT of overweight/obese patients compared with lean controls.CONCLUSIONAdaptive immune cells are the predominant immune cell constituent in human EAT and SAT. The presence of underlying cardiometabolic conditions, specifically obesity and diabetes, rather than cardiac disease phenotype appears to alter the inflammatory profile of EAT. Obese states markedly alter EAT metabolic and inflammatory signaling genes, underlining the impact of obesity on the EAT transcriptome profile.FUNDINGBarts Charity MGU0413, Abbott, Medical Research Council MR/T008059/1, and British Heart Foundation FS/13/49/30421 and PG/16/79/32419.


Assuntos
Tecido Adiposo/imunologia , Diabetes Mellitus/epidemiologia , Obesidade/epidemiologia , Pericardite/epidemiologia , Pericárdio/patologia , Imunidade Adaptativa , Tecido Adiposo/citologia , Tecido Adiposo/patologia , Idoso , Fatores de Risco Cardiometabólico , Comorbidade , Ponte de Artéria Coronária , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/metabolismo , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus/sangue , Diabetes Mellitus/imunologia , Diabetes Mellitus/metabolismo , Feminino , Humanos , Imunofenotipagem , Masculino , Pessoa de Meia-Idade , Obesidade/sangue , Obesidade/imunologia , Obesidade/metabolismo , Pericardite/imunologia , Pericardite/patologia , Pericárdio/cirurgia , RNA-Seq
6.
IEEE J Sel Top Quantum Electron ; 27(4): 7100412, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33716587

RESUMO

Small form-factor sensors are widely used in minimally invasive intravascular diagnostic procedures. Manufacturing complexities associated with miniaturizing current fiber-optic probes, particularly for multi-parameter sensing, severely constrain their adoption outside of niche fields. It is especially challenging to rapidly prototype and iterate upon sensor designs to optimize performance for medical devices. In this work, a novel technique to construct a microscale extrinsic fiber-optic sensor with a confined air cavity and sub-micron geometric resolution is presented. The confined air cavity is enclosed between a 3 µm thick pressure-sensitive distal diaphragm and a proximal temperature-sensitive plano-convex microlens segment unresponsive to changes in external pressure. Simultaneous pressure and temperature measurements are possible through optical interrogation via phase-resolved low-coherence interferometry (LCI). Upon characterization in a simulated intravascular environment, we find these sensors capable of detecting pressure changes down to 0.11 mmHg (in the range of 760 to 1060 mmHg) and temperature changes of 0.036 °C (in the range 34 to 50 °C). By virtue of these sensitivity values suited to intravascular physiological monitoring, and the scope of design flexibility enabled by the precision-fabricated photoresist microstructure, it is envisaged that this technique will enable construction of a wide range of fiber-optic sensors for guiding minimally invasive medical procedures.

7.
Front Cardiovasc Med ; 7: 525530, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33173786

RESUMO

Conventional intravascular ultrasound (IVUS) devices use piezoelectric transducers to electrically generate and receive US. With this paradigm, there are numerous challenges that restrict improvements in image quality. First, with miniaturization of the transducers to reduce device size, it can be challenging to achieve the sensitivities and bandwidths required for large tissue penetration depths and high spatial resolution. Second, complexities associated with manufacturing miniaturized electronic transducers can have significant cost implications. Third, with increasing interest in molecular characterization of tissue in-vivo, it has been challenging to incorporate optical elements for multimodality imaging with photoacoustics (PA) or near-infrared spectroscopy (NIRS) whilst maintaining the lateral dimensions suitable for intracoronary imaging. Optical Ultrasound (OpUS) is a new paradigm for intracoronary imaging. US is generated at the surface of a fiber optic transducer via the photoacoustic effect. Pulsed or modulated light is absorbed in an engineered coating on the fiber surface and converted to thermal energy. The subsequent temperature rise leads to a pressure rise within the coating, which results in a propagating ultrasound wave. US reflections from imaged structures are received with optical interferometry. With OpUS, high bandwidths (31.5 MHz) and pressures (21.5 MPa) have enabled imaging with axial resolutions better than 50 µm and at depths >20 mm. These values challenge those of conventional 40 MHz IVUS technology and show great potential for future clinical application. Recently developed nanocomposite coating materials, that are highly transmissive at light wavelengths used for PA and NIRS light, can facilitate multimodality imaging, thereby enabling molecular characterization.

8.
Europace ; 22(11): 1609-1618, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33006596

RESUMO

The aetiology of atrial fibrillation (AF) remains poorly understood, despite its growing prevalence and associated morbidity, mortality, and healthcare costs. Obesity is implicated in myriad different disease processes and is now recognized a major risk factor in the pathogenesis of AF. Moreover, the role of distinct adipose tissue depots is a matter of intense scientific interest with the depot directly surrounding the heart-epicardial adipose tissue (EAT) appearing to have the greatest correlation with AF presence and severity. Similarly, inflammation is implicated in the pathophysiology of AF with EAT thought to act as a local depot of inflammatory mediators. These can easily diffuse into atrial tissue with the potential to alter its structural and electrical properties. Various meta-analyses have indicated that EAT size is an independent risk factor for AF with adipose tissue expansion being inevitably associated with a local inflammatory process. Here, we first briefly review adipose tissue anatomy and physiology then move on to the epidemiological data correlating EAT, inflammation, and AF. We focus particularly on discussing the mechanistic basis of how EAT inflammation may precipitate and maintain AF. Finally, we review how EAT can be utilized to help in the clinical management of AF patients and discuss future avenues for research.


Assuntos
Fibrilação Atrial , Adiposidade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Humanos , Inflamação/epidemiologia , Obesidade/diagnóstico , Obesidade/epidemiologia , Pericárdio
9.
Eur Heart J Case Rep ; 4(4): 1-5, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32974463

RESUMO

BACKGROUND: Conventional cardiac resynchronization therapy (CRT) involves the placement of an epicardial left ventricular (LV) lead through the coronary venous tree. However, alternative approaches of delivering CRT have been sought for patients who fail to respond to conventional methods or for those where coronary venous anatomy is unfavourable. Biventricular pacing through an endocardial LV lead has potential advantages; however, the long-term clinical and safety data are not known. CASE SUMMARY: This article details a case series of four patients with endocardial LV leads; three of these for previously failed conventional CRT and a fourth for an inadvertently placed defibrillator lead. DISCUSSION: We describe the clinical course and adverse events associated with left-sided leads and subsequently describe the safe and feasible method of percutaneous extraction.

10.
Sci Rep ; 9(1): 5576, 2019 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-30944379

RESUMO

Miniaturised high-resolution imaging devices are valuable for guiding minimally invasive procedures such as vascular stent placements. Here, we present all-optical rotational B-mode pulse-echo ultrasound imaging. With this device, ultrasound transmission and reception are performed with light. The all-optical transducer in the probe comprised an optical fibre that delivered pulsed excitation light to an optical head at the distal end with a multi-walled carbon nanotube and polydimethylsiloxane composite coating. This coating was photoacoustically excited to generate a highly directional ultrasound beam perpendicular to the optical fibre axis. A concave Fabry-Pérot cavity at the distal end of an optical fibre, which was interrogated with a tuneable continuous-wave laser, served as an omnidirectional ultrasound receiver. The transmitted ultrasound had a -6 dB bandwidth of 31.3 MHz and a peak-to-peak pressure of 1.87 MPa, as measured at 1.5 mm from the probe. The receiver had a noise equivalent pressure <100 Pa over a 20 MHz bandwidth. With a maximum outer probe diameter of 1.25 mm, the probe provided imaging with an axial resolution better than 50 µm, and a real-time imaging rate of 5 frames per second. To investigate the capabilities of the probe, intraluminal imaging was performed in healthy swine carotid arteries. The results demonstrate that the all-optical probe is viable for clinical rotational ultrasound imaging.

11.
J Vis Exp ; (138)2018 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-30199033

RESUMO

Ultrasound is frequently used for guiding minimally invasive procedures, but visualizing medical devices is often challenging with this imaging modality. When visualization is lost, the medical device can cause trauma to critical tissue structures. Here, a method to track the needle tip during ultrasound image-guided procedures is presented. This method involves the use of a fiber-optic ultrasound receiver that is affixed within the cannula of a medical needle to communicate ultrasonically with the external ultrasound probe. This custom probe comprises a central transducer element array and side element arrays. In addition to conventional two-dimensional (2D) B-mode ultrasound imaging provided by the central array, three-dimensional (3D) needle tip tracking is provided by the side arrays. For B-mode ultrasound imaging, a standard transmit-receive sequence with electronic beamforming is performed. For ultrasonic tracking, Golay-coded ultrasound transmissions from the 4 side arrays are received by the hydrophone sensor, and subsequently the received signals are decoded to identify the needle tip's spatial location with respect to the ultrasound imaging probe. As a preliminary validation of this method, insertions of the needle/hydrophone pair were performed in clinically realistic contexts. This novel ultrasound imaging/tracking method is compatible with current clinical workflow, and it provides reliable device tracking during in-plane and out-of-plane needle insertions.


Assuntos
Imageamento Tridimensional/instrumentação , Agulhas , Fibras Ópticas , Ultrassonografia/instrumentação , Humanos , Transdutores
12.
Photoacoustics ; 11: 65-70, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30112279

RESUMO

Intravascular imaging in percutaneous coronary interventions can be an invaluable tool in the treatment of coronary artery disease. It is of significant interest to provide molecular imaging contrast that is complementary to structural contrast provided by optical coherence tomography (OCT) and intravascular ultrasound imaging (IVUS). In this study, we developed a dual-modality intravascular imaging probe comprising a commercial OCT catheter and a high sensitivity fiber optic ultrasound sensor, to provide both photoacoustic (PA) and OCT imaging. With PA imaging, the lateral resolution varied from 18 µm to 40 µm; the axial resolution was consistently in the vicinity of 45 µm. We demonstrated the clinical potential of the probe with 2-D circumferential PA and OCT imaging, and with multispectral PA imaging.

13.
Phys Med Biol ; 63(1): 015033, 2018 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-29186007

RESUMO

Here we describe methods for creating tissue-mimicking ultrasound phantoms based on patient anatomy using a soft material called gel wax. To recreate acoustically realistic tissue properties, two additives to gel wax were considered: paraffin wax to increase acoustic attenuation, and solid glass spheres to increase backscattering. The frequency dependence of ultrasound attenuation was well described with a power law over the measured range of 3-10 MHz. With the addition of paraffin wax in concentrations of 0 to 8 w/w%, attenuation varied from 0.72 to 2.91 dB cm-1 at 3 MHz and from 6.84 to 26.63 dB cm-1 at 10 MHz. With solid glass sphere concentrations in the range of 0.025-0.9 w/w%, acoustic backscattering consistent with a wide range of ultrasonic appearances was achieved. Native gel wax maintained its integrity during compressive deformations up to 60%; its Young's modulus was 17.4 ± 1.4 kPa. The gel wax with additives was shaped by melting and pouring it into 3D printed moulds. Three different phantoms were constructed: a nerve and vessel phantom for peripheral nerve blocks, a heart atrium phantom, and a placental phantom for minimally-invasive fetal interventions. In the first, nerves and vessels were represented as hyperechoic and hypoechoic tubular structures, respectively, in a homogeneous background. The second phantom comprised atria derived from an MRI scan of a patient with an intervening septum and adjoining vena cavae. The third comprised the chorionic surface of a placenta with superficial fetal vessels derived from an image of a post-partum human placenta. Gel wax is a material with widely tuneable ultrasound properties and mechanical characteristics that are well suited for creating patient-specific ultrasound phantoms in several clinical disciplines.


Assuntos
Átrios do Coração/diagnóstico por imagem , Nervos Periféricos/diagnóstico por imagem , Imagens de Fantasmas , Placenta/diagnóstico por imagem , Impressão Tridimensional/instrumentação , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Acústica , Biomimética , Módulo de Elasticidade , Feminino , Humanos , Modelos Anatômicos , Gravidez
14.
Med Image Comput Comput Assist Interv ; 10434: 637-645, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28948240

RESUMO

Ultrasound imaging is widely used for guiding minimally invasive procedures, including fetal surgery. Visualisation of medical devices such as medical needles is critically important and it remains challenging in many clinical contexts. During in-plane insertions, a needle can have poor visibility at steep insertion angles and at large insertion depths. During out-of-plane insertions, the needle tip can have a similar ultrasonic appearance to the needle shaft when it intersects with the ultrasound imaging plane. When the needle tip is not accurately identified, it can damage critical structures, with potentially severe consequences, including loss of pregnancy. In this paper, we present a tracking system to directly visualise the needle tip with an ultrasonic beacon. The waves transmitted by the beacon were received by an external ultrasound imaging probe. Pairs of co-registered images were acquired in rapid succession with this probe: a photoacoustic image obtained with the system in receive-only mode, and a conventional B-mode ultrasound image. The beacon comprised a custom elastomeric nanocomposite coating at the distal end of an optical fibre, which was positioned within the lumen of a commercial 22 gauge needle. Delivery of pulsed light to the coating resulted in the photoacoustic generation of ultrasonic waves. The measured tracking accuracies in water in the axial and lateral dimensions were 0.39±0.19 mm and 1.85±0.29 mm, respectively. To obtain a preliminary indication of the clinical potential of this ultrasonic needle tracking system, needle insertions were performed in an in vivo fetal sheep model. The results demonstrate that ultrasonic needle tracking with a fibre-optic transmitter is feasible in a clinically realistic fetal surgery environment, and that it could be useful to guide minimally invasive procedures by providing accurate visualisation of the medical device tip.


Assuntos
Feto/cirurgia , Agulhas , Ultrassonografia de Intervenção/métodos , Algoritmos , Animais , Feminino , Feto/diagnóstico por imagem , Gravidez , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos
15.
Sci Rep ; 7(1): 3674, 2017 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-28623369

RESUMO

Ultrasound is well suited for guiding many minimally invasive procedures, but its use is often precluded by the poor visibility of medical devices. When devices are not visible, they can damage critical structures, with life-threatening complications. Here, we developed the first ultrasound probe that comprises both focused and unfocused transducer elements to provide both 2D B-mode ultrasound imaging and 3D ultrasonic needle tracking. A fibre-optic hydrophone was integrated into a needle to receive Golay-coded transmissions from the probe and these data were processed to obtain tracking images of the needle tip. The measured tracking accuracy in water was better than 0.4 mm in all dimensions. To demonstrate the clinical potential of this system, insertions were performed into the spine and the uterine cavity, in swine and pregnant ovine models in vivo. In both models, the SNR ranged from 13 to 38 at depths of 22 to 38 mm, at out-of-plane distances of 1 to 15 mm, and at insertion angles of 33 to 42 degrees relative to the probe surface normal. This novel ultrasound imaging/tracking probe has strong potential to improve procedural outcomes by providing 3D needle tip locations that are co-registered to ultrasound images, while maintaining compatibility with current clinical workflow.

16.
Eur Heart J ; 38(17): 1336-1338, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-27469374
17.
Light Sci Appl ; 6(12): e17103, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30167220

RESUMO

High-frequency ultrasound imaging can provide exquisite visualizations of tissue to guide minimally invasive procedures. Here, we demonstrate that an all-optical ultrasound transducer, through which light guided by optical fibers is used to generate and receive ultrasound, is suitable for real-time invasive medical imaging in vivo. Broad-bandwidth ultrasound generation was achieved through the photoacoustic excitation of a multiwalled carbon nanotube-polydimethylsiloxane composite coating on the distal end of a 300-µm multi-mode optical fiber by a pulsed laser. The interrogation of a high-finesse Fabry-Pérot cavity on a single-mode optical fiber by a wavelength-tunable continuous-wave laser was applied for ultrasound reception. This transducer was integrated within a custom inner transseptal needle (diameter 1.08 mm; length 78 cm) that included a metallic septum to acoustically isolate the two optical fibers. The use of this needle within the beating heart of a pig provided unprecedented real-time views (50 Hz scan rate) of cardiac tissue (depth: 2.5 cm; axial resolution: 64 µm) and revealed the critical anatomical structures required to safely perform a transseptal crossing: the right and left atrial walls, the right atrial appendage, and the limbus fossae ovalis. This new paradigm will allow ultrasound imaging to be integrated into a broad range of minimally invasive devices in different clinical contexts.

18.
JACC Clin Electrophysiol ; 3(10): 1080-1088, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-29759489

RESUMO

OBJECTIVES: This study sought to assess the impact of ablation power and catheter irrigation during clinical radiofrequency ablation using impedance drop. BACKGROUND: In preclinical studies, ablation power and catheter irrigation are determinants of ablation efficacy. METHODS: Static 30-s left atrial ablations were delivered in patients undergoing their first atrial fibrillation ablation. Impedance drop during ablation (as a measure of efficacy) was compared using the following: the force time integral (FTI); the FTI-P (a cumulative multiple FTI and ablation power), and ablation index (AI), a weighted algorithm including contact force, power, and duration. Comparison was also made between a conventionally irrigated (SmartTouch [ST]) versus surround flow (STSF) contact force-sensing catheter. RESULTS: We analyzed 1,013 ablations. For both catheters, the Spearman correlation was higher between impedance drop and AI (rho = 0.89 ST, 0.84 STSF) than FTI-P (rho = 0.71 ST, 0.53 STSF) or FTI (rho = 0.77 ST, 0.52 STSF); p < 0.0005 for each. STSF ablations had lower minimum catheter tip temperatures (25°C [interquartile range (IQR): 25°C to 27°C] vs. 35°C [IQR: 34°C to 36°C]; p < 0.005), and lesser impedance drop per FTI or AI (p < 0.005 for both). For STSF, impedance drop plateaued sooner than for ST with respect to FTI (184g.s vs. 463g.s) and AI (370 AI vs. 430 AI). CONCLUSIONS: AI is a more complete ablation descriptor than is FTI or FTI-P, reflected by a stronger correlation with impedance drop. STSF ablations have lower impedance drop per AI or FTI than ST ablations do, suggesting different targets should be used if ablating guided by impedance drop with STSF. With ST, ablation beyond 430 AI provides minimal additional biophysical efficacy, suggesting an upper limit to use for clinical ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Irrigação Terapêutica/instrumentação , Irrigação Terapêutica/métodos , Idoso , Algoritmos , Fenômenos Biofísicos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Europace ; 18(5): 679-86, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26843584

RESUMO

AIMS: Catheter ablation of atrial fibrillation (AF) in patients with heart failure (HF) can improve left ventricular (LV) function and HF symptoms. We aimed to investigate whether long-term maintenance of sinus rhythm impacts on hard outcomes such as stroke and death. METHODS AND RESULTS: An international multicentre registry was compiled from seven centres for consecutive patients undergoing catheter ablation of AF. Long-term freedom from AF was examined in patients with and without HF. The impact of maintaining sinus rhythm on rates of stroke and death was also examined. A total of 1273 patients were included: 171 with HF and 1102 without. Median follow-up was 3.1 years (IQR 2.0-4.3). The final procedure success rate was no different for paroxysmal AF (PAF) (78.7 vs. 85.7%, P = 0.186), but significantly different for persistent AF (57.3 vs. 75.8%, P < 0.001). Multivariate analysis showed that HF independently predicted recurrent arrhythmia [hazard ratio (HR) 1.7, 95% confidence interval (CI) 1.2-2.4, P = 0.002]. New York Heart Association class decreased from 2.3 ± 0.7 at baseline to 1.5 ± 0.8 at follow-up (P < 0.001). Left ventricular ejection fraction (LVEF) increased from 34.3 ± 9.0 to 45.8 ± 12.8% (P < 0.001). Recurrent AF was strongly predictive of stroke or death in HF patients (HR 8.33, 95% CI 1.86-37.7, P = 0.001). CONCLUSION: Long-term success rates for persistent (but not paroxysmal) AF ablation are significantly lower in HF patients. Left ventricular function and HF symptoms were improved following ablation. In HF patients, recurrent arrhythmia strongly predicted stroke and death during follow-up.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Insuficiência Cardíaca/mortalidade , Acidente Vascular Cerebral/mortalidade , Idoso , Fibrilação Atrial/complicações , Austrália , Feminino , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Período Perioperatório , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/prevenção & controle , Volume Sistólico , Análise de Sobrevida , Resultado do Tratamento , Reino Unido , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...